info@integralmgs.com +90 322 352 08 93 Adana, TR

Medical Air Compressor Plants

Medical Air Compressor Plant
European Pharmacopoeia Compliant

Medical Air Compressor Plants

Integral Medical Air Plants are central supply systems designed for hospital mechanical infrastructure to deliver breathable medical air (4 Bar) and surgical tool driving air (7 Bar).

Air drawn from the atmosphere is stored in high-capacity vessels and passed through Desiccant Air Dryers (-46°C Dew Point) and a 5-stage filtration train to eliminate humidity, oil, and particles, fulfilling European Pharmacopoeia quality.

System Engineering & Safety Highlights

  • Modular Configurations: Simplex, Duplex, Triplex, or Quadruplex multi-compressor arrangements.
  • PLC Equal Aging: Smart control panel equalizing running hours across all compressors.
  • Sterile Bacterial Filter: Final stage 0.001 micron filtration guaranteeing 99.999% retention.
  • Continuous Dew Point Monitoring: Real-time humidity sensing (-46°C threshold).

Technical Documents & Drawings

PDF Datasheet

Tender Specification Text

Medical air plants shall comply with EN ISO 7396-1 and European Pharmacopoeia, featuring desiccant air dryers (-46°C Dew Point), 0.001 micron sterile bacterial filtration, PLC equal-aging control panel, and BMS interface.

Filtration Train & System Components
Component System Function Filtration Rating
Compressor Group Safely compresses ambient air Oil-Free Scroll or Oil-Injected Screw
Pre-Filter Protects system from large dust and water droplets 1 Micron
Desiccant Dryer Removes water vapor across twin towers Dew Point: -46°C Humidity level
Micro Filter Train Eliminates fine oil aerosol and particles 0.01 Micron / Oil: 0.01 mg/m³
Activated Carbon Filter Adsorbs hydrocarbon vapors and odors Odor & Organic Vapor Removal
Sterile Bacterial Filter Microbiological filtration prior to entering hospital pipeline 0.001 Micron (99.999% Efficiency)
Frequently Asked Questions (FAQ)

The medical air generated complies fully with the European Pharmacopoeia standards. Utilizing chemical desiccant dryers (-46°C Dew Point) and 5-stage filtration, the air is freed from humidity, oil, and bacteria.

Systems are configured in Simplex, Duplex, Triplex, or Quadruplex setups. The PLC control panel alternates the compressors to equalize running hours. If a compressor goes into fault or maintenance, standby units automatically kick in.

Yes. The compressor group conditions air to high pressure; dual-stage pressure regulators then reduce and separate the flow into 4 Bar breathable air and 7 Bar surgical tool driving air lines.

Newsletter